Every solar panel comes with a datasheet full of numbers. You don't need to be an engineer to understand the important ones.
Electrical specifications (at STC)
Most numbers are given at Standard Test Conditions (STC): 1,000 W/m² sunlight, 25°C cell temperature and a standard light spectrum.
Pmax (Maximum Power)
The panel's rated power, for example 550 Wp. "Wp" means "watt peak" — the power under STC.
Vmp and Imp
The voltage and current at maximum power.
Voc (Open Circuit Voltage)
The maximum voltage when no load is connected. Important for string design — installers must make sure string voltage stays within inverter limits, especially on cool mornings when Voc rises.
Isc (Short Circuit Current)
The maximum current when the panel's terminals are connected directly. Used for sizing fuses and cables.
Module Efficiency
How much of the sunlight hitting the panel is converted to electricity. Higher efficiency means more power from the same area.
Power Tolerance
Often shown as "0 to +5 W", meaning the panel will produce at least its rated power.
Temperature coefficients
- Pmax temperature coefficient (e.g., −0.30%/°C): How much power drops for each degree above 25°C. Smaller numbers (closer to zero) are better in hot climates.
- Voc and Isc temperature coefficients: Used by designers for voltage and current calculations.
NOCT or NMOT
Nominal Operating Cell Temperature gives a more realistic idea of how hot the panel runs in the field and the power output under those conditions.
Mechanical specifications
- Dimensions and weight
- Number and type of cells
- Glass thickness
- Frame material
- Junction box rating (e.g., IP68)
- Cable length and connector type
Certifications and ratings
Look for compliance with relevant IEC and BIS standards, and for subsidy projects, the ALMM listing and DCR certificate.
Warranty
Product warranty years and the performance warranty curve are usually shown on the datasheet.
The bottom line
Focus on Pmax, efficiency, temperature coefficient, warranty and certifications. Leave detailed voltage and current calculations to your installer — but now you'll understand what they're talking about.